A Salinity only
One NaCl figure per well and depth. Nothing else.
We are reading the water analyses out of the DISKOS fluid reports and collecting them in one Excel table: one row per water sample, with the well, the depth and what the lab measured. Every number can be traced back to the report page it came from.
One NaCl figure per well and depth. Nothing else.
The main salts and the isotopes for each water sample.
Every figure on the water pages, about 50 columns.
Please reply with A, B or C.
First three wells: 15/3-1 S, 15/3-11, 15/3-8. Amounts are in mg/l.
| Wellbore | Sample | Depth m | Type | Na mg/l | Cl mg/l | NaCl mg/l from Cl | TDS mg/l | Density | δ18O ‰ | δD ‰ | 87Sr/86Sr | Pages |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 15/3-11 | 1.01 (2018-06106-001) | 3927.45 | Formation water (WFS) | 38 900 | 72 300 | 119 188 | 121 000 | 1.086 | – | – | – | p. 3, 4 |
| 15/3-11 | 1.03 (2018-06106-003) | 3927.45 | Formation water (WFS) | – | – | – | – | – | 1.87 | -31.76 | 0.71425 | p. 9 |
| 15/3-1 S | FIT 2 | 4457.7 | Mud filtrate (filtrat de boue) | 11 800 | 12 233 | 20 166 | – | 1.025 | – | – | – | p. 2 |
| 15/3-1 S | FIT 8 | 4218.5 | Water (FIT) | 31 000 | 45 030 | 74 233 | – | 1.058 | – | – | – | p. 3 |
| 15/3-1 S | FIT 7 | 4064.3 | Water (FIT) | 10 766 | 8 864 | 14 612 | – | 1.027 | – | – | – | p. 4 |
| 15/3-8 | MDT run 2 chamber MPSR-710 | 4514.6 | Formation water (WFS) | 37 942 | 64 765 | 106 766 | – | 1.07611 | – | – | – | p. 21 |
| 15/3-8 | MDT run 2 chamber GA-194 | 4213.4 | Formation water (WFS) | 31 328 | 52 732 | 86 930 | – | 1.06365 | – | – | – | p. 22 |
| 15/3-8 | MDT run 4 chamber MPSR-756 | 4213.5 | Formation water (WFS) | 30 264 | 49 627 | 81 811 | – | 1.0644 | – | – | – | p. 24 |
| 15/3-8 | MDT run 4 chamber MPSR-36 | 4514.5 | Formation water (WFS) | 39 880 | 68 013 | 112 121 | – | 1.0777 | – | – | – | p. 25 |
Each report page is shown with the numbers we took outlined.
15_3-11_FLUID_ANALYSIS_2018-11-02_REPORT_1.PDF, page 3 of 21 · OCR quality in JSON: Reliable
| Analyte | Value | Unit | Printed | Check |
|---|---|---|---|---|
| Na | 38 900 | mg/l | 38900 mg/l | no check |
| Ca | 6 150 | mg/l | 6150 mg/l | no check |
| Mg | 584 | mg/l | 584 mg/l | no check |
| Ba | 1 370 | mg/l | 1370 mg/l | no check |
| Fe | 30.8 | mg/l | 30,8 mg/l | no check |
| Sr | 990 | mg/l | 990 mg/l not located | no check |
| K | 986 | mg/l | 986 mg/l | no check |
| B | 26.9 | mg/l | 26,9 mg/l | no check |
| S | 3.7 | mg/l | 3,7 mg/l | no check |
| As | 0.00276 | mg/l | 2,76 µg/l | no check |
| Pb | 0.0823 | mg/l | 82,3 µg/l | no check |
| Cd | 0.00383 | mg/l | 3,83 µg/l | no check |
| Cu | 0.394 | mg/l | 394 µg/l | no check |
| Cr | 0.368 | mg/l | 368 µg/l | no check |
| Hg | 0.000447 | mg/l | 0,447 µg/l | no check |
| Mn | 2.08 | mg/l | 2080 µg/l | no check |
| Ni | 1.17 | mg/l | 1170 µg/l | no check |
| Se | 0.00889 | mg/l | 8,89 µg/l | no check |
| Zn | 0.901 | mg/l | 901 µg/l | no check |
| Ag | <0.001 | mg/l | <1 µg/l | no check |
| Cl | 72 300 | mg/l | 72300 mg/l | no check |
| Br | 510 | mg/l | 510 mg/l | no check |
| SO4 | <20 | mg/l | <20 mg/l | no check |
| Alkalinity | 10.6 | mmol/l | 10,60 mmol/l | no check |
| TDS | 121 000 | mg/l | 121000 mg/l | no check |
These have no column in the sample table yet. They are in the Excel draft's Values sheet.
| Printed label | Value | Unit |
|---|---|---|
| Sulphate from sulphur, ICP | 11 | mg/l |
| Ionbalance (cation/anion) | 1,6 | % |
15_3-11_FLUID_ANALYSIS_2018-11-02_REPORT_1.PDF, page 4 of 21 · OCR quality in JSON: Reliable
| Analyte | Value | Unit | Printed | Check |
|---|---|---|---|---|
| pH | 5.6 | pH | 5,6 pH | no check |
| Density | 1.086 | - | 1,086 - | no check |
| Resistivity | 0.07 | ohm·m | 0,070 ohm·m | no check |
| NH4 | 190 | mg/l | 190 mg/l | no check |
These have no column in the sample table yet. They are in the Excel draft's Values sheet.
| Printed label | Value | Unit |
|---|---|---|
| Resistivity at temperature | 21,5 | °C |
| Suspended solids | 109 | mg/l |
| Benzene | <0.1 | mg/l |
| Toluene | <0.2 | mg/l |
| Ethylbenzene | <0.2 | mg/l |
| p-Xylene | <0.2 | mg/l |
| m-Xylene | <0.2 | mg/l |
| o-Xylene | <0.2 | mg/l |
| Etanoic acid | 84 | mg/l |
| Propionic acid | <20 | mg/l |
| n-Butanoic acid | <20 | mg/l |
| n-Pentanoic acid | <20 | mg/l |
| n-Hexanoic acid | <20 | mg/l |
| Nitrate | 0,52 | mg/l |
| Nitrite in water | <0.001 | mg/l |
| Nitrogen, N (tot) | 150 | mg/l |
| Phosphate, (PO4)3- | 24 | mg/l |
15_3-11_FLUID_ANALYSIS_2018-11-02_REPORT_1.PDF, page 9 of 21 · OCR quality in JSON: Reliable
Isotopes; same depth as 1.01
| Analyte | Value | Unit | Printed | Check |
|---|---|---|---|---|
| δ34S | 10.98 | - | 10,98 - | no check |
| δD | -31.76 | - | -31,76 - | no check |
| δ18O | 1.87 | - | 1,87 - | no check |
| 87Sr/86Sr | 0.71425 | - | 0,714250 - | no check |
These have no column in the sample table yet. They are in the Excel draft's Values sheet.
| Printed label | Value | Unit |
|---|---|---|
| Gas water ratio GWR @15°C, 1atm | 2,24 | - |
| Volume gas @15°C 1atm | 872 | ml |
| Volume liquid @15°C | 390 | ml |
| Compressibility factor, 15°C | 0,9965 | - |
| Inferior Calorific Value, ISO | 26534,6 | \( KJ/m^3 \) |
| Superior Calorific Value, ISO | 29366,3 | \( KJ/m^3 \) |
| Real relative Density, 15 °C | 0,8991 | - |
| Real density of mixture | 1,1018 | \( kg/Sm^3 \) |
| Moleweight | 26,0 | kg/kmol |
| Critical Pressure | 5400,2 | kPa |
| Critical Temperature | 233,5 | K |
| Nitrogene | 1,28 | mol% |
| Carbondioxide | 29,37 | mol% |
| Methane | 62,47 | mol% |
| Ethane | 4,19 | mol% |
| Propane | 1,70 | mol% |
| i-Butane | 0,15 | mol% |
| n-Butane | 0,48 | mol% |
| Cyclopentane | 0,01 | mol% |
| i-Pentane | 0,11 | mol% |
| Neopentane | <0.01 | mol% |
| n-Pentane | 0,14 | mol% |
| Hexanes | 0,08 | mol% |
| Heptanes+ | 0,02 | mol% |
| Ra (226) | 25 ± 3,1 | bq/l |
| Ra (228) | 8,9 ± 1,1 | bq/l |
| Pb (210) | <= 2,0 | bq/l |
15_3-1_S_FLUID_ANALYSIS_1975-08-03_REPORT_1.PDF, page 2 of 5 · OCR quality in JSON: Figure-dominated
Mud filtrate: not formation water
| Analyte | Value | Unit | Printed | Check |
|---|---|---|---|---|
| Ca | 68 | mg/l | 0,068 g/l68 mg/l ÷ 20.04 = 3.4 meq; printed 3.39 | meq consistent |
| Mg | traces | Traces g/l | no check | |
| K | 380 | mg/l | 0,380 g/l380 mg/l ÷ 39.1 = 9.7 meq; printed 9.72 | meq consistent |
| Na | 11 800 | mg/l | 11,800 g/l11800 mg/l ÷ 22.99 = 513.3 meq; printed 513.11 | meq consistent |
| Fe | 0 | mg/l | 0 g/l not located | no check |
| Cl | 12 233 | mg/l | 12,233 g/l12233 mg/l ÷ 35.45 = 345.1 meq; printed 345.01 | meq consistent |
| SO4 | 5 758 | mg/l | 5,758 g/l5758 mg/l ÷ 48.03 = 119.9 meq; printed 119.88 | meq consistent |
| CO3 | 180 | mg/l | 0,180 g/l180 mg/l ÷ 30.0 = 6.0 meq; printed 6 | meq consistent |
| HCO3 | 3 478 | mg/l | 3,478 g/l3478 mg/l ÷ 61.02 = 57.0 meq; printed 57 | meq consistent |
| NaCl (reported) | 20 170 | mg/l | 20,17 g/l | no check |
| pH | 8.46 | pH | 8,46 pH | no check |
| Density | 1.025 | - | 1025 - | no check |
| Dry extract | 34 000 | mg/l | 34 g/l not located | no check |
These have no column in the sample table yet. They are in the Excel draft's Values sheet.
| Printed label | Value | Unit |
|---|---|---|
| i+ | Traces | g/l |
15_3-1_S_FLUID_ANALYSIS_1975-08-03_REPORT_1.PDF, page 3 of 5 · OCR quality in JSON: Reliable
| Analyte | Value | Unit | Printed | Check |
|---|---|---|---|---|
| Caprinted on the NH4 row | 359 | mg/l | 0,359 g/l359 mg/l ÷ 20.04 = 17.9 meq; printed 17.91. As NH4 it would be 19.9 | moved |
| Mgprinted on the Ca row | 10 | mg/l | 0,010 g/l10 mg/l ÷ 12.15 = 0.8 meq; printed 0.82. As Ca it would be 0.5 | moved |
| Kprinted on the Mg row | 1 420 | mg/l | 1,420 g/l1420 mg/l ÷ 39.1 = 36.3 meq; printed 36.32. As Mg it would be 116.9 | moved |
| Naprinted on the K row | 31 000 | mg/l | 31,000 g/l31000 mg/l ÷ 22.99 = 1348.4 meq; printed 1348. As K it would be 792.8 | moved |
| Liprinted on the Na row | traces | Traces g/l | moved | |
| Cl | 45 030 | mg/l | 45,030 g/l45030 mg/l ÷ 35.45 = 1270.2 meq; printed 1269.99 | meq consistent |
| SO4 | 55 | mg/l | 0,055 g/l55 mg/l ÷ 48.03 = 1.1 meq; printed 1.15 | meq consistent |
| CO3 | 0 | mg/l | 0 g/l not located0 mg/l ÷ 30.0 = 0.0 meq; printed 0 | meq consistent |
| HCO3 | 6 285 | mg/l | 6,285 g/l6285 mg/l ÷ 61.02 = 103.0 meq; printed 103 | meq consistent |
| NaCl (reported) | 74 240 | mg/l | 74,24 g/l | no check |
| pH | 7.5 | pH | 7,50 pH | no check |
| Density | 1.058 | - | 1058 - | no check |
15_3-1_S_FLUID_ANALYSIS_1975-08-03_REPORT_1.PDF, page 4 of 5 · OCR quality in JSON: Reliable
| Analyte | Value | Unit | Printed | Check |
|---|---|---|---|---|
| Caprinted on the NH4 row | 308 | mg/l | 0,308 g/l308 mg/l ÷ 20.04 = 15.4 meq; printed 15.37. As NH4 it would be 17.1 | moved |
| Mgprinted on the Ca row | 21 | mg/l | 0,021 g/l21 mg/l ÷ 12.15 = 1.7 meq; printed 1.73. As Ca it would be 1.0 | moved |
| Kprinted on the Mg row | 933 | mg/l | 0,933 g/l933 mg/l ÷ 39.1 = 23.9 meq; printed 23.86. As Mg it would be 76.8 | moved |
| Naprinted on the K row | 10 766 | mg/l | 10,766 g/l10766 mg/l ÷ 22.99 = 468.3 meq; printed 468.15. As K it would be 275.3 | moved |
| Liprinted on the Na row | traces | Traces g/l | moved | |
| Cl | 8 864 | mg/l | 8,864 g/l8864 mg/l ÷ 35.45 = 250.0 meq; printed 249.99 | meq consistent |
| SO4 | 6 358 | mg/l | 6,358 g/l6358 mg/l ÷ 48.03 = 132.4 meq; printed 132.38 | meq consistent |
| CO3 | 0 | mg/l | 0 g/l not located0 mg/l ÷ 30.0 = 0.0 meq; printed 0 | meq consistent |
| HCO3 | 8 298 | mg/l | 8,298 g/l8298 mg/l ÷ 61.02 = 136.0 meq; printed 135.99 | meq consistent |
| NaCl (reported) | 14 610 | mg/l | 14,61 g/l | no check |
| pH | 7.93 | pH | 7.93 pH | no check |
| Density | 1.027 | - | 1027 - | no check |
| Dry extract | 35 000 | mg/l | 35 g/l not located | no check |
15_3-8_FLUID_ANALYSIS_REPORT_1.PDF, page 21 of 49 · OCR quality in JSON: Reliable
Glycol contamination
| Analyte | Value | Unit | Printed | Check |
|---|---|---|---|---|
| Li | 45 | mg/l | 45 mg/l45 mg/l ÷ 6.94 = 6.5 meq; printed 7 | meq consistent |
| Na | 37 942 | mg/l | 37942 mg/l37942 mg/l ÷ 22.99 = 1650.4 meq; printed 1650 | meq consistent |
| K | 980 | mg/l | 980 mg/l not located980 mg/l ÷ 39.1 = 25.1 meq; printed 25 | meq consistent |
| Mg | 205 | mg/l | 205 mg/l205 mg/l ÷ 12.15 = 16.9 meq; printed 17 | meq consistent |
| Ca | 1 252 | mg/l | 1252 mg/l1252 mg/l ÷ 20.04 = 62.5 meq; printed 62 | meq consistent |
| Sr | 650 | mg/l | 650 mg/l650 mg/l ÷ 43.81 = 14.8 meq; printed 15 | meq consistent |
| Ba | 3 002 | mg/l | 3002 mg/l3002 mg/l ÷ 68.66 = 43.7 meq; printed 44 | meq consistent |
| Fe | 0.2 | mg/l | 0.2 mg/l0.2 mg/l ÷ 27.92 = 0.0 meq; printed 0 | meq consistent |
| Acetate | 273 | mg/l | 273 mg/l273 mg/l ÷ 59.04 = 4.6 meq; printed 5 | meq consistent |
| Formate | 261 | mg/l | 261 mg/l261 mg/l ÷ 45.02 = 5.8 meq; printed 6 | meq consistent |
| Cl | 64 765 | mg/l | 64765 mg/l64765 mg/l ÷ 35.45 = 1826.9 meq; printed 1824 | meq consistent |
| SO4 | 70 | mg/l | 70 mg/l70 mg/l ÷ 48.03 = 1.5 meq; printed 1 | meq consistent |
| Br | 244 | mg/l | 244 mg/l244 mg/l ÷ 79.9 = 3.1 meq; printed 3 | meq consistent |
| Conductivity | 140 | mS/cm | 140.0 mS/cm | no check |
| Density | 1.07611 | g/ml | 1.07611 g/ml | no check |
These have no column in the sample table yet. They are in the Excel draft's Values sheet.
| Printed label | Value | Unit |
|---|---|---|
| Sulfide (mg/l) | <0.1 | mg/l |
15_3-8_FLUID_ANALYSIS_REPORT_1.PDF, page 22 of 49 · OCR quality in JSON: Reliable
Glycol contamination
| Analyte | Value | Unit | Printed | Check |
|---|---|---|---|---|
| Li | 40 | mg/l | 40 mg/l40 mg/l ÷ 6.94 = 5.8 meq; printed 6 | meq consistent |
| Na | 31 328 | mg/l | 31328 mg/l31328 mg/l ÷ 22.99 = 1362.7 meq; printed 1362 | meq consistent |
| K | 879 | mg/l | 879 mg/l879 mg/l ÷ 39.1 = 22.5 meq; printed 22 | meq consistent |
| Mg | 78 | mg/l | 78 mg/l78 mg/l ÷ 12.15 = 6.4 meq; printed 6 | meq consistent |
| Ca | 592 | mg/l | 592 mg/l592 mg/l ÷ 20.04 = 29.5 meq; printed 30 | meq consistent |
| Sr | 276 | mg/l | 276 mg/l276 mg/l ÷ 43.81 = 6.3 meq; printed 6 | meq consistent |
| Ba | 2 014 | mg/l | 2014 mg/l2014 mg/l ÷ 68.66 = 29.3 meq; printed 29 | meq consistent |
| Fe | 0.3 | mg/l | 0.3 mg/l0.3 mg/l ÷ 27.92 = 0.0 meq; printed 0 | meq consistent |
| Acetate | 348 | mg/l | 348 mg/l348 mg/l ÷ 59.04 = 5.9 meq; printed 6 | meq consistent |
| Formate | 198 | mg/l | 198 mg/l198 mg/l ÷ 45.02 = 4.4 meq; printed 4 | meq consistent |
| Cl | 52 732 | mg/l | 52732 mg/l52732 mg/l ÷ 35.45 = 1487.5 meq; printed 1485 | meq consistent |
| SO4 | 39 | mg/l | 39 mg/l39 mg/l ÷ 48.03 = 0.8 meq; printed 1 | meq consistent |
| Br | 248 | mg/l | 248 mg/l248 mg/l ÷ 79.9 = 3.1 meq; printed 3 | meq consistent |
| CO3 | 0 | mg/l | 0 mg/l0 mg/l ÷ 30.0 = 0.0 meq; printed 0 | meq consistent |
| HCO3 | 934 | mg/l | 934 mg/l934 mg/l ÷ 61.02 = 15.3 meq; printed 15 | meq consistent |
| pH | 6.15 | pH | 6.15 pH | no check |
| Conductivity | 108.3 | mS/cm | 108.3 mS/cm | no check |
| Density | 1.06365 | g/ml | 1.06365 g/ml | no check |
These have no column in the sample table yet. They are in the Excel draft's Values sheet.
| Printed label | Value | Unit |
|---|---|---|
| GWR (Sm3/Sm3) | 3.1 | Sm3/Sm3 |
| H2S in gas (ppm) | 6 | ppm |
| Sulfide (mg/l) | <0.1 | mg/l |
15_3-8_FLUID_ANALYSIS_REPORT_1.PDF, page 24 of 49 · OCR quality in JSON: Reliable
| Analyte | Value | Unit | Printed | Check |
|---|---|---|---|---|
| Li | 31 | mg/l | 31 mg/l31 mg/l ÷ 6.94 = 4.5 meq; printed 4 | meq consistent |
| Na | 30 264 | mg/l | 30264 mg/l30264 mg/l ÷ 22.99 = 1316.4 meq; printed 1316 | meq consistent |
| K | 821 | mg/l | 821 mg/l821 mg/l ÷ 39.1 = 21.0 meq; printed 21 | meq consistent |
| Mg | 16 | mg/l | 16 mg/l16 mg/l ÷ 12.15 = 1.3 meq; printed 1 | meq consistent |
| Ca | 560 | mg/l | 560 mg/l560 mg/l ÷ 20.04 = 27.9 meq; printed 28 | meq consistent |
| Sr | 414 | mg/l | 414 mg/l414 mg/l ÷ 43.81 = 9.4 meq; printed 9 | meq consistent |
| Ba | 2 070 | mg/l | 2070 mg/l2070 mg/l ÷ 68.66 = 30.1 meq; printed 30 | meq consistent |
| Acetate | 261 | mg/l | 261 mg/l261 mg/l ÷ 59.04 = 4.4 meq; printed 4 | meq consistent |
| Formate | 11 | mg/l | 11 mg/l11 mg/l ÷ 45.02 = 0.2 meq; printed 0 | meq consistent |
| Cl | 49 627 | mg/l | 49627 mg/l49627 mg/l ÷ 35.45 = 1399.9 meq; printed 1398 | meq consistent |
| SO4 | 22 | mg/l | 22 mg/l22 mg/l ÷ 48.03 = 0.5 meq; printed 0 | meq consistent |
| Br | 254 | mg/l | 254 mg/l254 mg/l ÷ 79.9 = 3.2 meq; printed 3 | meq consistent |
| Density | 1.0644 | g/ml | 1.0644 g/ml | no check |
15_3-8_FLUID_ANALYSIS_REPORT_1.PDF, page 25 of 49 · OCR quality in JSON: Reliable
Transferred with synthetic oil
| Analyte | Value | Unit | Printed | Check |
|---|---|---|---|---|
| Li | 50 | mg/l | 50 mg/l50 mg/l ÷ 6.94 = 7.2 meq; printed 7 | meq consistent |
| Na | 39 880 | mg/l | 39880 mg/l39880 mg/l ÷ 22.99 = 1734.7 meq; printed 1734 | meq consistent |
| K | 1 132 | mg/l | 1132 mg/l1132 mg/l ÷ 39.1 = 29.0 meq; printed 29 | meq consistent |
| Mg | 13 | mg/l | 13 mg/l13 mg/l ÷ 12.15 = 1.1 meq; printed 1 | meq consistent |
| Ca | 1 160 | mg/l | 1160 mg/l1160 mg/l ÷ 20.04 = 57.9 meq; printed 58 | meq consistent |
| Sr | 747 | mg/l | 747 mg/l747 mg/l ÷ 43.81 = 17.1 meq; printed 17 | meq consistent |
| Ba | 2 952 | mg/l | 2952 mg/l2952 mg/l ÷ 68.66 = 43.0 meq; printed 43 | meq consistent |
| Acetate | 165 | mg/l | 165 mg/l165 mg/l ÷ 59.04 = 2.8 meq; printed 3 | meq consistent |
| Formate | 7 | mg/l | 7 mg/l7 mg/l ÷ 45.02 = 0.2 meq; printed 0 | meq consistent |
| Cl | 68 013 | mg/l | 68013 mg/l68013 mg/l ÷ 35.45 = 1918.6 meq; printed 1916 | meq consistent |
| SO4 | 19 | mg/l | 19 mg/l19 mg/l ÷ 48.03 = 0.4 meq; printed 0 | meq consistent |
| Br | 283 | mg/l | 283 mg/l283 mg/l ÷ 79.9 = 3.5 meq; printed 4 | meq consistent |
| Density | 1.0777 | g/ml | 1.0777 g/ml | no check |